ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual

This document introduces the emergency stop function of the ABB ACS880-07/07LC/17/17LC/37/37LC drives, including function introduction, working principle, electrical installation and start-up test.


ABB ACS880-07/07LC/17/17LC/37/37LC Drives Emergency Stop Function User Manual - cover page
Brand
ABB
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
72
File format
PDF
File size
1.3 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
50274B3F10FA6622AAE825A3F9F8F85F

About this manual

This manual provides instructions for installing, configuring, and operating the emergency stop function for ABB ACS880-07/07LC/17/17LC/37/37LC drives. It covers safety precautions, wiring, parameter settings, and validation procedures for stop categories 0 and 1, including time and ramp monitoring. The manual also includes technical data, compliance standards, and maintenance guidelines for safety circuits.

The document is intended for qualified electrical professionals and includes diagrams, safety warnings, and detailed operational steps for integrating emergency stop functionality into drive systems.

What's inside

  • Safety instructions
  • Electrical installation
  • Parameter settings
  • Use of the safety function
  • Start-up and acceptance test
  • Maintenance
  • Technical data
  • Related standards and directives

Specifications

Safety performance with safety pulse encodersSee FSE-31 pulse encoder interface module user’s manual (3AXD50000016597 [English])
Safety data calculation assumptions for main contactorSwitched at low load current (normal use, ~0%, AC-1), used for emergency stop once a month, used for ordinary on/off once a day
Safety data calculation assumptions for main breakerSwitched at low load current (normal use, ~0%, AC-1), used for emergency stop once a month, used for ordinary on/off once a week

Frequently asked questions

What safety standards does this manual comply with?

The manual complies with EN ISO 12100:2010, EN ISO 13849-1:2015, EN ISO 13849-2:2012, EN ISO 13850:2015, EN 60204-1:2018, IEC 61326-3-1:2017, IEC 61508-1:2010, IEC 61508-2:2010, IEC 61511-1:2016, EN 61800-5-2:2007, IEC 61800-5-2:2016, EN 62061:2005 + AC:2010 + A1:2013 + A2:2015, and European Machinery Directive 2006/42/EC.

Who is this manual intended for?

Only qualified electrical professionals with sufficient knowledge about functional, machine, and process safety are permitted to install, start up, and maintain the safety circuit.

What are the safety precautions before working on the drive?

Disconnect all possible voltage sources, lock out and tag out, wait 5 minutes for capacitors to discharge, and verify de-energized status using a voltage tester.