Key facts
- Brand
- Motorola
- Model
- PowerPC 603e
- Category
- Processors
- Industry
- Electronics
- Documents
- 4
- Languages
- EN
- Last added
- 2026-11-18
Start here

Motorola PowerPC 603e RISC Microprocessor Part Number Specifications Data Sheet
This application-specific data sheet defines unique part numbers for PowerPC 603e RISC microprocessors manufactured by Motorola. It describes changes to recommended operating conditions and revised electrical specifications from the PID6-603e Hardware Specification, and states that specifications not addressed are unchanged.
The document lists part number differences by CPU frequency, package, and operating conditions, summarizes known errata, provides revised DC, thermal, AC, and clock timing specifications, and includes ordering information for the covered parts.
Motorola PowerPC 603e specifications
| Junction temperature for TN-suffix parts | -40 to 105 °C |
|---|---|
| Maximum processor frequency | 133.33 MHz |
| VCO frequency range | 100 to 266.66 MHz |
| SYSCLK bus frequency range | 16.67 to 66.67 MHz |
| Internal PLL relock time | 100 µs |
Source: Motorola PowerPC 603e RISC Microprocessor Part Number Specifications Data Sheet
All Motorola PowerPC 603e documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What does this data sheet define?
It defines unique part numbers for Motorola-manufactured PowerPC 603e microprocessors and changes to the PID6-603e hardware specifications.
From: Motorola PowerPC 603e RISC Microprocessor Part Number Specifications Data Sheet
What happened to the 120 MHz offering?
Motorola discontinued the 120 MHz offering and encourages customers who need 120 MHz to buy the 133 MHz part.
From: Motorola PowerPC 603e RISC Microprocessor Part Number Specifications Data Sheet
Is the 120 MHz offering available in this revision?
No, Motorola has discontinued the 120 MHz offering for this revision.
From: Motorola PID6-603e PowerPC 603e RISC Microprocessor Part Number Specifications
How long must HRESET be held asserted after the PLL-relock time during power-on reset?
HRESET must be held asserted for a minimum of 255 bus clocks.
From: Motorola PID6-603e PowerPC 603e RISC Microprocessor Part Number Specifications
What is the maximum core supply voltage?
The absolute maximum rating for the core supply voltage is 2.75 V.
What is the recommended operating range for the I/O supply voltage?
The recommended operating range for the I/O supply voltage is 3.135 V to 3.465 V.