Key facts
- Brand
- Agilent
- Model
- 600 Series
- Documents
- 11
- Languages
- EN · ZH · IT
- Last added
- 2026-10-10
Start here

Agilent TriScroll 600 Series Dry Scroll Vacuum Pump Installation and Operation Manual
The document serves as an Installation and Operation Manual for the TriScroll 600 Series Dry Scroll Vacuum Pump. It covers general information regarding storage, unpacking, and installation requirements, along with detailed safety guidelines.
The guide outlines specific procedures for starting up and shutting down the pump, followed by maintenance instructions including troubleshooting charts and tooling kits. Technical sections detail electrical connections for single and three-phase motors, mechanical connections, and specifications such as full load motor currents.
Agilent 600 Series specifications
| Frequency range (89641A) | DC – 6000 MHz |
|---|---|
| Frequency tuning resolution | 1 mHz |
| Initial frequency accuracy | 100 ppb |
| Aging (frequency) | 1 ppb/day |
| Nominal impedance | 50 ohms |
| Third-order intermodulation distortion (IF/baseband mode) | < –70 dBc |
Source: Agilent 89600 Series Vector Signal Analyzer Data Sheet
All Agilent 600 Series documents by type
Ratings, dimensions and ordering codes, for selection and design work.
- Agilent U1240/U1250/U1600 Series Handheld Digital Multimeters and Oscilloscopes Product Leaflet 16 p
- Agilent Cary 600 Series FTIR Spectrometers Brochure 8 p
- Agilent Cary 600 Series FTIR guaranteed specifications Manual 6 p
- Agilent Cary 600 Series FTIR Spectrometers Brochure 8 p
- Agilent 600 Series FTIR Spectroscopy Solutions Brochure 20 p
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the frequency range of the 89641A model?
The 89641A covers a frequency range from DC to 6000 MHz.
From: Agilent 89600 Series Vector Signal Analyzer Data Sheet
What is the initial frequency accuracy for these analyzers?
The initial frequency accuracy is specified as 100 ppb.
From: Agilent 89600 Series Vector Signal Analyzer Data Sheet
What is the sampling rate of the U1600 series oscilloscope?
The U1600 series oscilloscope provides a sampling rate of 200 MSa/s.
From: Agilent U1240/U1250/U1600 Series Handheld Digital Multimeters and Oscilloscopes Product Leaflet
What overvoltage protection rating does the U1240 series have?
The U1240 series includes CAT III 1000 V overvoltage protection.
From: Agilent U1240/U1250/U1600 Series Handheld Digital Multimeters and Oscilloscopes Product Leaflet
What is the maximum spectral range of the Cary 600 Series FTIR systems?
The systems offer a complete spectral range from UV at 50,000 cm-1 to far IR at 20 cm-1.
What is the maximum scan speed for kinetic analysis?
The systems support ultra-rapid kinetics with speeds greater than 110 spectra per second.