Agilent 600 Series Manuals

ManualLib has 11 documents for the Agilent 600 Series: 3 datasheets, 5 product leaflets, 2 user manuals. Every file can be read online or downloaded as a PDF for free.

Datasheet 3Product Leaflet 5User Manual 2

Key facts

Brand
Agilent
Model
600 Series
Documents
11
Languages
EN · ZH · IT
Last added
2026-10-10

Start here

Agilent TriScroll 600 Series Dry Scroll Vacuum Pump Installation and Operation Manual

Agilent TriScroll 600 Series Dry Scroll Vacuum Pump Installation and Operation Manual

User Manual 54 pages · 1.9 MB · EN

The document serves as an Installation and Operation Manual for the TriScroll 600 Series Dry Scroll Vacuum Pump. It covers general information regarding storage, unpacking, and installation requirements, along with detailed safety guidelines.

The guide outlines specific procedures for starting up and shutting down the pump, followed by maintenance instructions including troubleshooting charts and tooling kits. Technical sections detail electrical connections for single and three-phase motors, mechanical connections, and specifications such as full load motor currents.

Read online

Agilent 600 Series specifications

Frequency range (89641A)DC – 6000 MHz
Frequency tuning resolution1 mHz
Initial frequency accuracy100 ppb
Aging (frequency)1 ppb/day
Nominal impedance50 ohms
Third-order intermodulation distortion (IF/baseband mode)< –70 dBc

Source: Agilent 89600 Series Vector Signal Analyzer Data Sheet

All Agilent 600 Series documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the frequency range of the 89641A model?

The 89641A covers a frequency range from DC to 6000 MHz.

From: Agilent 89600 Series Vector Signal Analyzer Data Sheet

What is the initial frequency accuracy for these analyzers?

The initial frequency accuracy is specified as 100 ppb.

From: Agilent 89600 Series Vector Signal Analyzer Data Sheet

What is the sampling rate of the U1600 series oscilloscope?

The U1600 series oscilloscope provides a sampling rate of 200 MSa/s.

From: Agilent U1240/U1250/U1600 Series Handheld Digital Multimeters and Oscilloscopes Product Leaflet

What overvoltage protection rating does the U1240 series have?

The U1240 series includes CAT III 1000 V overvoltage protection.

From: Agilent U1240/U1250/U1600 Series Handheld Digital Multimeters and Oscilloscopes Product Leaflet

What is the maximum spectral range of the Cary 600 Series FTIR systems?

The systems offer a complete spectral range from UV at 50,000 cm-1 to far IR at 20 cm-1.

From: Agilent Cary 600 Series FTIR Spectrometers Brochure

What is the maximum scan speed for kinetic analysis?

The systems support ultra-rapid kinetics with speeds greater than 110 spectra per second.

From: Agilent Cary 600 Series FTIR Spectrometers Brochure