ABB ACS150 Manuals

ManualLib has 7 documents for the ABB ACS150: 3 user manuals, 1 application note. Every file can be read online or downloaded as a PDF for free.

User Manual 3Application Note 1

Key facts

Brand
ABB
Model
ACS150
Industry
Industrial
Documents
7
Languages
NL · ZH · PT · EN
Last added
2026-11-22

Start here

ABB ACS150 Variable Frequency Drive User Manual

ABB ACS150 Variable Frequency Drive User Manual

User Manual 179 pages · 3.4 MB · PT

This manual is for the ABB ACS150 variable frequency drive, rated 0.37 to 4 kW (0.5 to 5 hp). It covers safety, mechanical and electrical installation, wiring, start-up, control through I/O, and use of the integrated programming panel.

It also describes application macros, actual signals and parameters, fault finding, maintenance, technical data, and an appendix on process PID control. This manual is written in Portuguese.

Read online

ABB ACS150 specifications

Power rating range0.37...4 kW, 0.5...5 hp
Document revisionRev C
Effective date2011-01-01

Source: ABB ACS150 drives (0.37 4 kW 0.5 5 hp) User manual

All ABB ACS150 documents by type

Product Leaflet 1

Questions answered in these manuals

What power range do the ACS150 drives cover?

The manual covers ACS150 drives rated 0.37...4 kW (0.5...5 pk).

From: ABB ACS150 Variable Frequency Drive User Manual

Where can ABB drive manuals be found online?

Manuals and other product documents are available in PDF format on the Internet at www.abb.com/drives under Document Library.

From: ABB ACS150 Variable Frequency Drive User Manual

What is the power range of the ACS150 inverter?

The ACS150 inverter covers 0.37 to 4 kW.

From: ABB ACS150 Inverter User Manual

What is the document number of this manual?

The manual is identified by document number 3ABD00018671.

From: ABB ACS150 Inverter User Manual

Who may install and maintain the ACS150?

Only qualified electricians are authorized to perform installation and maintenance work on the frequency converter.

From: ABB ACS150 Variable Frequency Drive User Manual

How long must I wait after disconnecting power before working on the drive?

Wait 5 minutes for the intermediate circuit capacitors to discharge.

From: ABB ACS150 Variable Frequency Drive User Manual