Key facts
Start here

3M 6000 Series Filter Cartridges User Manual
This is the Chinese-language instruction sheet for 3M 6000 series gas and vapor filter cartridges (滤毒盒), covering cartridge types such as the 6035, 6051, 6054, 6055, 6057, 6059, 6096, 6098 and 6099. It explains that the cartridges form a self-contained filtering respirator together with 3M 6000/7000/7500 series half masks or 3M 6000/7000 series full facepieces, and that 3M 5000 series particulate filters can also be used with the 6000 series cartridges.
The document lists the standards marked on the cartridges, the CE certification background, and the situations in which the product must not be used, followed by the steps for fitting and removing a cartridge and for judging when it needs replacing. It then gives cartridge color codes, cartridge classes with their maximum use concentrations, the P1 to P3 particulate filter classes, storage and transport conditions with a 5-year storage period, and a list of low-boiling organic vapors with use limits for the 6098 AXP3 cartridge. This manual is written in Chinese.
3M 6000 Series specifications
| Certified standard, 6000 series cartridges | EN 141:2000 |
|---|---|
| Certified standard, 6098 cartridge | EN 371:1992 |
| Certified standard, 6035 cartridge | EN 143:2000 |
| Storage temperature range | -10 °C to +30 °C |
| Storage humidity limit | Not above 90% relative humidity |
| Storage period | 5 years from the date of manufacture under normal storage conditions |
| Maximum use concentration, class 1 cartridges with half masks | 1000 ppm (0.1% vol) or 10xAPF, whichever is lower |
| Maximum use concentration, class 2 cartridges with half masks | 5000 ppm (0.5% vol) or 10xAPF, whichever is lower |
| Maximum use time, mercury vapor cartridge | 30 hours |
All 3M 6000 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Which standards do the 3M 6000 series filter cartridges meet?
The 6000 series cartridges meet EN 141:2000, with two exceptions: the 3M 6098 meets EN 371:1992 and the 3M 6035 meets EN 143:2000.
Which 3M full facepieces can the cartridges be used with?
They can be used with 3M 6000/7000 series full facepieces, as well as with 3M 6000/7000/7500 series half masks.
What does the OV designation mean?
OV indicates NIOSH approval for certain organic vapors.
From: 3M 6000 Series and 7000 Series Half and Full Facepiece Respirators Product Matrix
Which filters are compatible with the 6000 and 7000 series respirators?
Filters such as P95, P100, N95 and specialty filters (e.g., AM/MA, AG) are listed as compatible.
From: 3M 6000 Series and 7000 Series Half and Full Facepiece Respirators Product Matrix