3M 3015VP Vapour Permeable Air Barrier Product Leaflet
3M™ Vapour Permeable Air Barrier 3015VP is a membrane designed for building applications, allowing water vapour to pass while blocking air and water. It features a high-tack acrylic adhesive that requires no primer on most surfaces. The product meets standards including ASTM E2178 and CAN/ULC S741, and is suitable for use in temperatures ranging from -40°C to 116°C. It is compatible with various sealants and adheres well to concrete, metal, and gypsum boards. This manual is written in Chinese.
Read online3M 3015VP specifications
| Air Permeance | 0.0009 L/s.m² (0.0002 cfm/ft²) |
|---|---|
| Air Leakage Rate Classification | A1 |
| Flame Spread Rating | Class A |
| Liner Thickness | 0.078 mm (3 mils) |
| Total Thickness | 0.50 mm (15 mils) |
| Tensile Strength | 8.1 MPa (1177 psi) |
| Elongation at Break | 40% |
| Lap Adhesion (Stainless Steel) | 0.44 N/mm (50 oz./in) |
| Water Vapour Transmission (Desiccant Method) | 685 ng/Pa.s.m² (12 US Perms) |
| Service Temperature Range | -40°C to 116°C (-40°F to 240°F) |
Source: 3M 3015VP Vapour Permeable Air Barrier Product Leaflet
All 3M 3015VP documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What standards does 3M 3015VP meet?
It meets ASTM E2178 and CAN/ULC S741-8.
From: 3M 3015VP Vapour Permeable Air Barrier Product Leaflet
What is the service temperature range for 3M 3015VP?
It can be used from -40°C to 116°C (-40°F to 240°F).
From: 3M 3015VP Vapour Permeable Air Barrier Product Leaflet
Does 3M 3015VP need a primer before installation?
It can be applied to a wide variety of sheathing substrates typically without priming. Surfaces must be clean, dry and free of grease, oil, un-bonded paint or corrosion.
From: 3M 3015VP Vapour Permeable Air Barrier Installation Guidelines
What temperature range can the membrane be applied in?
It can be applied in temperatures as low as -18°C to 66°C (0°F to 150°F), which helps extend the building season.
From: 3M 3015VP Vapour Permeable Air Barrier Installation Guidelines
Is a primer needed for installation?
No primer is needed on most construction surfaces.
From: 3M 3015VP Air Barrier with Permeable Backing Installation Guide
Can the product be installed vertically or horizontally?
Yes, it can be installed vertically or horizontally.
From: 3M 3015VP Air Barrier with Permeable Backing Installation Guide