Analog Devices ADR420/ADR421/ADR423/ADR425 Voltage Reference Datasheet

Analog Devices ADR420/ADR421/ADR423/ADR425 Voltage Reference Datasheet

Datasheet 24 pages · 632 KB · ZH

The ADR420/ADR421/ADR423/ADR425 series are high‑precision, low‑noise XFET® voltage reference devices offered by Analog Devices. They provide stable reference voltages of 2.048 V, 2.50 V, 3.00 V and 5.00 V with low temperature coefficients and excellent long‑term stability.

The devices are supplied in 8‑pin SOIC or 8‑pin MSOP packages, operate over a wide supply range (4 V‑18 V for ADR420, up to 7 V‑18 V for ADR425), and are suitable for precision data‑acquisition, medical instrumentation, fiber‑optic networking and industrial process control. This manual is written in Chinese.

Read online

Analog Devices ADR423 specifications

Output voltage (ADR420)2.048 V
Temperature coefficient (ADR420)0.05 ppm/°C (typical)
Supply voltage range (ADR420)4 V to 18 V
Static current (max)0.5 mA
Load regulation70 ppm/mA
Package options8‑pin SOIC or 8‑pin MSOP
Operating temperature range–40 °C to +125 °C

Source: Analog Devices ADR420/ADR421/ADR423/ADR425 Voltage Reference Datasheet

All Analog Devices ADR423 documents by type

Questions answered in these manuals

What is the output voltage of the ADR420 reference?

The ADR420 provides a 2.048 V reference output.

From: Analog Devices ADR420/ADR421/ADR423/ADR425 Voltage Reference Datasheet

What is the operating temperature range for the ADR42x series?

All devices in the series operate from –40 °C to +125 °C.

From: Analog Devices ADR420/ADR421/ADR423/ADR425 Voltage Reference Datasheet

What is the output voltage range for the ADR425?

The ADR425 provides a typical 5.00 V output; A‑grade devices range from 4.994 V to 5.006 V and B‑grade devices from 4.998 V to 5.002 V.

From: Analog Devices ADR420/ADR421/ADR423/ADR425 Voltage Reference Datasheet

What is the maximum supply voltage allowed for these voltage references?

The absolute maximum supply voltage is 18 V.

From: Analog Devices ADR420/ADR421/ADR423/ADR425 Voltage Reference Datasheet