HP 241 Protein Sequencer (N+C) Manuals

ManualLib has 5 documents for the HP 241 Protein Sequencer (N+C): 1 product leaflet, 1 other, 2 service manuals, 1 user manual. Every file can be read online or downloaded as a PDF for free.

Product Leaflet 1Other 1Service Manual 2User Manual 1

Key facts

Brand
HP
Model
241 Protein Sequencer (N+C)
Documents
5
Languages
EN
Last added
2012-07-05

Start here

HP 241 Protein Sequencer N+C Service Methods Technical Note

HP 241 Protein Sequencer N+C Service Methods Technical Note

User Manual 5 pages · 77 KB · EN

This document describes technical methods for N-terminal protein membrane sequencing using the Hewlett-Packard 241 Protein Sequencer. It outlines specific reagents required for C-terminal sequencing versus N-terminal analysis and explains that these methods are suitable for samples in the low nanomole to low picomole range applied onto a HP Zitex strip.

Read online

HP 241 Protein Sequencer (N+C) specifications

Sample Rangelow nanomole to low picomole range
Waste Volumeless than 1 mL/cycle
Reagent SourceHewlett-Packard

Source: Hewlett-Packard HP 241 Protein Sequencer N+C Service Manual

All HP 241 Protein Sequencer (N+C) documents by type

Service Manual 2

Disassembly, diagnostics and part numbers, for repair.

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

Which instruments require the use of the TFA bottle cap remover?

Both the HP 241 Protein Sequencing System and the HP G1004B Protein Chemistry Station require the use of this tool.

From: HP 241 Protein Sequencer (N+C) service manual(3)

What is the purpose of the TFA bottle cap remover?

It is a tool designed for safe removal of caps from TFA bottles to prevent accidental contact with the corrosive acid.

From: HP 241 Protein Sequencer (N+C) service manual(3)

What methods are available for switching between sequencing chemistries?

The N-to-C 4.0 method is used when switching from the N-terminal to the C-terminal chemistry, and the C-to-N 4.0 method is used when switching from the C-terminal to the N-terminal chemistry.

From: Hewlett-Packard 241 Protein Sequencer N-to-C and C-to-N Methods Technical Note

What column configuration is required for these methods?

The sequencer column configuration consists of an empty reverse-phase (RP) sample column mated with an empty strong anion exchange (SAX) column.

From: Hewlett-Packard 241 Protein Sequencer N-to-C and C-to-N Methods Technical Note

What is the purpose of the Cycle 1 method?

It provides a longer initial drying time and a pause for proper HPLC column equilibration after switching from C-terminal sequencing.

From: Hewlett-Packard HP 241 Protein Sequencer N+C Service Manual

Which reagents are used for N-terminal sequencing?

Reagents 1R, 2R, 3R, and TH-Std are not utilized; the document focuses on methods using specific coupling agents like DPP-ITC.

From: Hewlett-Packard HP 241 Protein Sequencer N+C Service Manual