Philips SM5 30C Series Surface Mounted Luminaire Installation Manual
This document covers installation, wiring, sensor upgrade, and maintenance for the Philips SM5 30C series surface-mounted luminaire. It includes dimensions, electrical characteristics, inrush current data, and safety notes.
Topics include PoE cable requirements, DALI wiring, push-in connections, LightEngine handling, and multilingual safety statements.
Philips SM5 30C specifications
| Supply voltage | 220-240 V |
|---|---|
| Frequency | 50/60 Hz |
| Operating temperature | 10 °C to 35 °C |
| Glow wire temperature | 650 °C |
| Laser class | Class 2M |
| PoE cable type | UTP CAT5E or CAT6 |
| PoE cable maximum length | 20 m |
| PoE cable minimum bend radius | 4x cable diameter |
| Inrush current Imax | 21 A |
| Inrush current Tref | 280 µs |
Source: Philips SM5 30C Series Surface Mounted Luminaire Installation Manual
All Philips SM5 30C documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What is the maximum length for a PoE Ethernet cable?
The maximum length of the cable is 20 meters.
From: Philips SM5 30C Series Surface Mounted Luminaire Installation Manual
Which Ethernet cable types are specified for PoE?
Use UTP (Unshielded Twisted Pair) CAT5E or CAT6 cable.
From: Philips SM5 30C Series Surface Mounted Luminaire Installation Manual
Can the LED light source be replaced?
No. The light source of this luminaire is not replaceable; when it reaches end of life the whole luminaire shall be replaced.
From: Philips TrueLine SM530C/SM531C/SM534C Luminaire Installation Guide
Which Ethernet cable is required for POE?
Use UTP (unshielded twisted pair) CAT5E or CAT6 cable, with a maximum length of 20 meters and a minimum bend radius of 4x the cable diameter.