Installation and specification information for the Philips TrueLine SM530C, SM531C and SM534C surface-mounted indoor luminaires.
The Philips TrueLine SM530C/SM531C/SM534C are surface-mounted indoor luminaires rated 220 V 240 V, 50Hz 60Hz, with IP20 and IK02. They are offered in StandAlone, Line End and Line Feature versions, and the light source is not replaceable.
The document covers mounting dimensions, push-in wiring for DALI/POE/PSD/SRD, sensor replacement, POE cabling using UTP CAT5E or CAT6 up to 20 meters, and maintenance such as cleaning with a damped cloth and disconnecting before servicing. This manual is written in Chinese.
| Rated voltage | 220 V 240 V |
|---|---|
| Max. operating temperature | 35 °C |
| Min. operating temperature | 10 °C |
| Light source replaceable | No - replace whole luminaire |
No. The light source of this luminaire is not replaceable; when it reaches end of life the whole luminaire shall be replaced.
Use UTP (unshielded twisted pair) CAT5E or CAT6 cable, with a maximum length of 20 meters and a minimum bend radius of 4x the cable diameter.
Disconnect the luminaire from power before servicing.
Use a damped cloth (no dripping water); for fingerprints use a cleaner appropriate for polycarbonate/PMMA plastics. Do not clean with a dry cloth.