Key facts
- Brand
- Philips
- Model
- L200
- Industry
- Industrial
- Documents
- 3
- Languages
- ZH
- Last added
- 2012-03-19
Start here

Philips BHL 125 L200 HID Ballast Manual
This manual for the Philips BHL 125 L200 HID ballast lists the overall and operating parameters, including voltage, frequency, power consumption and power factor. It also details wiring requirements, temperature limits and safety information.
Additional sections cover the physical dimensions, mounting hole spacing, packaging details and bar‑code information. The document includes the product’s weight and regulatory markings. This manual is written in Chinese.
Philips L200 specifications
| Lamp power | 400 |
|---|---|
| Application code | L200 |
| Line voltage | 220 V |
| Frequency | 50 Hz |
| Input current with power-factor correction | 2.15 A |
| Input current without power-factor correction | 3.25 A |
| Supply voltage safety (AC) | -10%/+10% |
| Supply voltage performance (AC) | -8%/+6% |
| Output power at 100% power factor | 0.85 (min) |
| Power factor without compensation | 0.60 |
| Ballast power loss | 21.8 W |
| Connector type | Screws |
| Maximum winding temperature (tw) | 130 C (max) |
| Delta-T normal conditions | 70 C |
| Length A1 | 150.0 mm |
| Fixed hole distance A2 | 135.0 mm |
| Width B1 | 75.5 mm |
| Height C1 | 64.5 mm |
| Fixing hole diameter D1 | 6.2 mm |
| ENEC certificate | No |
| CCC certificate | Yes |
All Philips L200 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What lamps is the Philips BHL 400 L200 ballast used with?
It is an HID basic ballast for HPL and HPI(PLUS) lamps.
What is the line voltage of the BHL 400 L200?
220 V.
What is the input voltage and frequency for the BHL 125 L200?
The ballast operates at 220 V and 50 Hz.
What are the physical dimensions of the ballast?
The dimensions are 117.0 mm × 102.0 mm × 57.1 mm.