TOREX XC6101~XC6107, XC6111~XC6117 Voltage Detector Datasheet

TOREX XC6101~XC6107, XC6111~XC6117 Voltage Detector Datasheet

Datasheet 26 pages · 521 KB · EN

The document describes the XC6101~XC6107 and XC6111~XC6117 series as groups of high-precision, low current consumption voltage detectors utilizing CMOS technology. These ICs incorporate a reference voltage source, delay circuit, comparator, and output driver to provide reset signals with selectable release delays.

Key features include a detect voltage range from 1.6V to 5.0V in 100mV increments, six selectable watchdog timeout periods ranging from 6.25ms to 1.6s, and seven release delay times. The series offers two output configurations: VDFL (low when detected) and VDFH (high when detected), with options for CMOS or N-channel open drain outputs.

Read online

Torex XC6111 specifications

Detect Voltage Range1.6V ~ 5.0V, +2%
Hysteresis Range (XC6101~XC6107)VDF x 5%, TYP.
Hysteresis Range (XC6111~XC6117)VDF x 0.1%, TYP.
Operating Voltage Range1.0V ~ 6.0V
Detect Voltage Temperature Characteristics< 100ppm/°C (TYP)
Watchdog Timeout Periods6.25ms to 1.6sec
Release Delay Times3.13ms to 1.6sec
Output Configuration OptionsN-channel open drain, CMOS

Source: TOREX XC6101~XC6107, XC6111~XC6117 Voltage Detector Datasheet

All Torex XC6111 documents by type

Questions answered in these manuals

What is the detect voltage range for this series?

The detect voltages are internally fixed from 1.6V to 5.0V in increments of 100mV.

From: TOREX XC6101~XC6107, XC6111~XC6117 Voltage Detector Datasheet

Can the watchdog pin be left unconnected?

Yes, for XC6101~XC6105 and XC6111~XC6115 series ICs, the WD pin can be left open if the watchdog function is not used.

From: TOREX XC6101~XC6107, XC6111~XC6117 Voltage Detector Datasheet

What is the detect voltage range of the XC6101‑XC6107 series?

The detect voltage range is 1.6 V to 5.0 V with a ±2 % tolerance and 100 mV increments.

From: Torex XC6101‑XC6107 XC6111‑XC6117 Series Datasheet

What watchdog timeout periods can be selected?

Watchdog timeout periods can be set from 6.25 ms up to 1.6 s.

From: Torex XC6101‑XC6107 XC6111‑XC6117 Series Datasheet

How many watchdog timeout periods are provided and what is their range?

Six watchdog timeout periods are provided, ranging from 6.25 ms to 1.6 s.

From: Torex XC6101-XC6107 / XC6111-XC6117 Series Voltage Detector Datasheet

Are the XC6101 series devices RoHS compliant?

Yes, they are EU RoHS compliant and lead‑free.

From: Torex XC6101-XC6107 / XC6111-XC6117 Series Voltage Detector Datasheet