Hitachi KFR-72LW/R(D) Air Conditioner User Manual
This manual provides detailed instructions for installing, operating, and maintaining the Hitachi KFR-72LW/R(D) split‑type air conditioner. It includes safety warnings, wiring diagrams, and step‑by‑step procedures for both indoor and outdoor units.
Key sections cover product performance specifications, control panel functions, filter cleaning reminders, troubleshooting tips, and recommended installation locations to ensure optimal performance and energy efficiency. This manual is written in Chinese.
Hitachi KFR-72LW specifications
| Model (indoor/outdoor unit) | KFR-72L/J3 and KFR-72W/J3 |
|---|---|
| Power supply (indoor/outdoor) and frequency | Single-phase/three-phase, 50 Hz |
| Rated voltage (indoor/outdoor) | 220/380 V |
| Rated input power (cooling/heating) | 2865/2380 W |
| Cooling/heating capacity | 7200/8500 W |
| Dehumidification | 2.7 kg/h |
| Air volume | 1050 m3/h |
| Air swing louver | Yes |
| Standby power | About 5.0 W |
| Indoor air purification | Yes |
| Noise (indoor/outdoor) | 48/57 dB(A) |
| Cooling energy efficiency ratio (EER) | 2.51 |
| Heating coefficient of performance (COP) | 3.57 |
| Net weight (indoor/outdoor) | 41/67 kg |
| Gross weight (indoor/outdoor) | 49/83 kg |
Source: Hitachi KFR-72LW/J3, KFR-72W/J3 and KFR-72L/J3 Air Conditioner Use and Installation Manual
All Hitachi KFR-72LW documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Hitachi KFR-72LW/M(D) User Manual 16 p
- Hitachi KFR-72LW/J3, KFR-72W/J3 and KFR-72L/J3 Air Conditioner Use and Installation Manual 16 p
- Hitachi KFR-72LW/J3 Air Conditioner User Manual 16 p
- Hitachi KFR-72LW/S Air Conditioner User Manual 16 p
- Hitachi KFR-72LW/P Air Conditioner User Manual 17 p
- Hitachi KFR-72LW/R(D) Air Conditioner User Manual 18 p
- Hitachi KFR-72LW/Q Air Conditioner User Manual 18 p
- Hitachi KFR-72LW/BpA Air Conditioner User Manual 18 p
- Hitachi KFR-72LW/BpB Air Conditioner User Manual 18 p
Questions answered in these manuals
How do I set the sleep timer on the unit?
Follow the steps in the “睡眠定時器的設定法” section, which describe selecting the desired duration and confirming the setting on the remote control.
What is the maximum recommended length for the refrigerant pipe?
The manual states the maximum total pipe length should not exceed 15 m.
Why can the air conditioner not restart immediately after stopping?
After stopping, the unit cannot restart for about 3 minutes, except after a power failure and restoration; this protects the compressor and is not a malfunction.
From: Hitachi KFR-72LW/J3, KFR-72W/J3 and KFR-72L/J3 Air Conditioner Use and Installation Manual
Which phenomena during operation are normal and not faults?
Short current sounds at start or stop, water dripping from the indoor unit during cooling, and frost or condensation under certain outdoor temperature and humidity conditions are described as normal.
From: Hitachi KFR-72LW/J3, KFR-72W/J3 and KFR-72L/J3 Air Conditioner Use and Installation Manual
What is the purpose of the fuzzy control system?
It automatically adjusts the machine's start and stop times based on indoor temperature changes to provide a comfortable environment and save energy.
How does the automatic dehumidification work?
The function starts automatically when the room temperature is higher than the set temperature and stops once the temperature drops to the set level.