The guide details the physical appearance of the unit, installation procedures, wiring diagrams for main and control circuits, and step-by-step operation instructions including startup and motor running tests. Furthermore, it explains various drive functions such as monitoring modes, parameter settings, input/output terminal configurations, PID control, and communication protocols like Modbus. This manual is written in Chinese.
Hitachi NE-S1 series specifications
| Maximum surrounding air temperature rating | 50 ºC |
|---|---|
| Motor overload protection trip level | max. 150 % of FLA |
| Suitable supply circuit | not more than 100,000 rms symmetrical amperes, 240 V maximum |
| Required wire type | 60/75ºC CU wire only |
| NES1-007S tightening torque and wire range | 1.8 N.m; 14~12 AWG |
Source: Hitachi NE-S1 Series Inverter Safety Precautions Manual
All Hitachi NE-S1 series documents by type
The shortest path to a working setup, usually only a few pages.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What does this guide cover?
This guide covers the usage and maintenance of the Hitachi NE-S1 Series VFD, including safety, installation, wiring, operation, and specifications.
From: Hitachi NE-S1 Series NT3411Z VFD Quick Reference Guide
What should be done before installing or operating the drive?
You must read this guide carefully and follow all instructions, safety information, and precautions recorded within it.
From: Hitachi NE-S1 Series NT3411Z VFD Quick Reference Guide
What should be read before installing or operating the NE-S1 series inverter?
The Instruction Manual and appended documents must be read thoroughly before installing or operating the inverter.
From: Hitachi NE-S1 Series Inverter Safety Precautions Manual
How long must I wait after turning off power before inspecting the inverter?
Turn off the power supply and wait at least 10 minutes, and confirm that the Charge lamp is off before inspection.
From: Hitachi NE-S1 Series Inverter Safety Precautions Manual
What safety precautions must be taken before inspecting the Hitachi NE-S1 series inverter?
Before inspecting the inverter, you must turn off the power supply and wait for at least 10 minutes.
What is the maximum surrounding air temperature rating for the Hitachi NE-S1 series inverter?
The maximum surrounding air temperature rating is 50 ºC.