Hitachi WJ200 Series Inverter Quick Reference Guide
The Quick Reference Guide for the Hitachi WJ200 series inverters presents essential data for installation, wiring, and safety. It includes UL cautions, warnings, terminal screw sizes, and recommended wire gauges for each model variant.
The document also lists fuse requirements, detailed inverter specifications such as input/output ratings, rated capacity, starting torque, and weight. Safety sections cover safe‑disable functions, proof‑test intervals, and recommended external safety devices.
Hitachi WJ200 Series specifications
| Rated input voltage (Single-phase) | 200V-15% to 240V +10%, 50/60Hz ±5% |
|---|---|
| Rated output voltage (Three-phase) | 200 to 240V |
| Starting torque | 200% at 0.5Hz Without resistor |
| Braking method | With resistor, DC braking |
All Hitachi WJ200 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
The shortest path to a working setup, usually only a few pages.
Questions answered in these manuals
What wire gauge is required for the WJ200-007S model?
The required wire range is AWG12 (3.3mm²).
What wire temperature rating is required for the WJ200-015S model?
You must use 75°C Cu wire only.
How long must the power be disconnected before wiring?
Wait at least 10 minutes after disconnecting power to ensure capacitors are discharged.
What is the maximum input voltage for the pulse input terminal?
The maximum input voltage is 24VDC.
What type of wire is recommended for the WJ200 series?
The manual recommends using 60/75°C Cu wire or equivalent for specific models.
What is the minimum wait time required after turning off the input power before performing maintenance?
You must wait at least five minutes after turning off the input power supply before performing maintenance or an inspection.