Key facts
- Brand
- Analog Devices
- Model
- ADXL345
- Industry
- Industrial
- Documents
- 4
- Languages
- ZH · EN
- Last added
- 2026-11-21
Start here

Analog Devices ADXL345 3-Axis Digital Accelerometer Datasheet
The Analog Devices ADXL345 is a small, thin, low-power 3-axis digital accelerometer. It provides user-selectable measurement ranges of ±2 g, ±4 g, ±8 g, and ±16 g, with digital output data in 16-bit two's complement format accessible through SPI (3-wire or 4-wire) or I2C interfaces.
The device supports activity and inactivity monitoring, single and double-tap detection, free-fall detection, and a 32-level FIFO buffer. It operates over a supply voltage range of 2.0 V to 3.6 V, an interface voltage range of 1.7 V to VDD I/O, and a temperature range of −40 °C to +85 °C. This manual is written in Chinese.
Analog Devices ADXL345 specifications
| Measurement range | ±2 g, ±4 g, ±8 g, ±16 g |
|---|---|
| Output resolution | 10-bit fixed; full resolution up to 13 bits |
| Sensitivity | 3.9 mg/LSB typical at ±2 g |
| Supply voltage range | 2.0 V to 3.6 V |
| Interface voltage range | 1.7 V to VDD I/O |
| Operating temperature range | −40 °C to +85 °C |
| Output data rate | 0.1 Hz to 3200 Hz |
| Standby current | 0.1 µA |
Source: Analog Devices ADXL345 3-Axis Digital Accelerometer Datasheet
All Analog Devices ADXL345 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What digital interfaces does the ADXL345 support?
It supports SPI (3-wire or 4-wire) and I2C digital interfaces.
From: Analog Devices ADXL345 3-Axis Digital Accelerometer Datasheet
What measurement ranges are available on the ADXL345?
The user can select ±2 g, ±4 g, ±8 g, or ±16 g measurement ranges.
From: Analog Devices ADXL345 3-Axis Digital Accelerometer Datasheet
What is the voltage supply range for the ADXL345 accelerometer?
The ADXL345 requires a voltage supply between 2.0 and 3.6 V.
What is the operating voltage range of the ADXL345?
The ADXL345 operates from 2.0 V to 3.6 V.
What measurement ranges does the ADXL345 support?
It supports selectable ranges of ±2 g, ±4 g, ±8 g, and ±16 g.
What is the operating voltage range of the ADXL345?
The device operates from 2.0 V to 3.6 V supply voltage.