Key facts
- Brand
- Analog Devices
- Model
- ADXL103
- Industry
- Industrial
- Documents
- 3
- Languages
- ZH · EN
- Last added
- 2022-10-19
Start here

Analog Devices ADXL103/ADXL203 Accelerometer Datasheet
The ADXL103/ADXL203 are complete, high-performance, low-power, single/dual-axis accelerometers that provide conditioned voltage outputs. All functions are integrated into a single-chip IC, offering full-scale acceleration measurement ranges of ±1.7 g, ±5 g, or ±18 g.
These devices can simultaneously measure dynamic acceleration (such as vibration) and static acceleration (such as gravity). With a typical noise floor of 110 µg/√Hz, they allow for the resolution of signals below 1 mg (0.06° tilt) in tilt detection applications using narrow bandwidths (<60 Hz). Bandwidth is selectable from 0.5 Hz to 2.5 kHz by using capacitors on the XOUT and YOUT pins. This manual is written in Chinese.
Analog Devices ADXL103 specifications
| Measurement Range | +1.7 g |
|---|---|
| Resolution | 1 mg at 60 Hz |
| Operating Voltage | 3 to 6 V |
| Quiescent Supply Current | 0.7 to 1.1 mA |
| Temperature Range | -40°C to +125°C |
| Shock Survival | 3500 g |
| Sensitivity | 960 to 1040 mV/g |
| Noise Density | 110 µg/√Hz |
| Bandwidth | 0.5 Hz to 2.5 kHz |
Source: Analog Devices ADXL103/ADXL203 Accelerometer Datasheet
All Analog Devices ADXL103 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the physical size of the ADXL103/ADXL203 accelerometer package?
The device is available in a 5 mm × 5 mm × 2 mm LCC package.
From: Analog Devices ADXL103/ADXL203 Accelerometer Datasheet
What is the maximum acceleration the device can withstand during shock?
The accelerometer has an impact resistance capability of 3,500 g.
From: Analog Devices ADXL103/ADXL203 Accelerometer Datasheet
Which models are qualified for automotive applications?
The ADXL103W, ADW22035, ADXL203W, ADW22293, and ADW22037 are automotive‑qualified models.
From: Analog Devices ADXL103/ADXL203 Accelerometer Datasheet
What is the typical power consumption at a 5 V supply?
Typical quiescent current is 700 pA at 5 V.
From: Analog Devices ADXL103/ADXL203 Accelerometer Datasheet
What is the measurement range of the ADXL103/ADXL203?
The measurement range is ±1.7 g.
From: Analog Devices ADXL103/ADXL203 Accelerometer Datasheet
What is the operating voltage range?
The operating voltage range is 3 to 6 V.
From: Analog Devices ADXL103/ADXL203 Accelerometer Datasheet