Honeywell HIH-4000 Series Voltage Output Humidity Sensor Datasheet
Honeywell HIH-4000 series humidity sensors are designed for high-volume OEM use and provide a near-linear voltage output proportional to relative humidity. Typical supply current is 200 µA, making them suitable for low-power and battery-operated systems.
The series offers instrument-grade RH sensing with interchangeability, accuracy, fast response, stability, and resistance to humidity, dust, dirt, oils, and common chemicals. Applications include refrigeration, HVAC, medical equipment, drying equipment, instrumentation, battery-powered systems, and OEM assemblies. This manual is written in Chinese.
Honeywell HIH-4000 Series specifications
| Supply voltage | 4 to 5.8 Vdc |
|---|---|
| Supply current | Typical 200 µA, maximum 500 µA |
| Accuracy (best-fit straight line) | ±3.5 %RH |
| Repeatability | ±0.5 %RH |
| Response time | 15 s (1/e in slowly moving air) |
| Operating temperature | -40 to 85 °C |
| Operating humidity | 0 to 100 %RH (non-condensing) |
Source: Honeywell HIH-4000 Series Voltage Output Humidity Sensor Datasheet
All Honeywell HIH-4000 Series documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What is the typical supply current of the HIH-4000 series?
The typical supply current is 200 µA, with a maximum of 500 µA.
From: Honeywell HIH-4000 Series Voltage Output Humidity Sensor Datasheet
What is the voltage output formula for the HIH-4000 series?
Vout = Vsupply [0.0062 (sensor RH) + 0.16] at 25 °C.
From: Honeywell HIH-4000 Series Voltage Output Humidity Sensor Datasheet
What is the typical supply current of the HIH-4000 sensor?
The sensor typically draws 200 µA and can draw up to 500 µA.
What accuracy does the HIH-4000 sensor provide?
It offers a best‑fit line accuracy of ±3.5 %RH.