Honeywell HMR3200/HMR3300 Digital Compass User Manual

Honeywell HMR3200/HMR3300 Digital Compass User Manual

User Manual 3 pages · 123 KB · ZH

This manual describes the Honeywell HMR3200 and HMR3300 digital compass modules, which offer compact size (25 mm × 37 mm × 10 mm) and low weight (≈7 g). The devices measure three‑axis magnetic fields with a range of ±2 Gauss and provide tilt‑angle measurement up to ±60°.

The document details electrical requirements (6‑15 VDC supply), UART and SPI communication protocols, pin assignments, and example command formats for direction and magnetic‑field output. It also lists the available demo kits and software support for easy integration into navigation and guidance systems. This manual is written in Chinese.

Read online

Honeywell HMR330 specifications

Tilt‑angle range±60°
Module size25 mm × 37 mm × 10 mm
Weight (HMR3200)7.25 g
Operating temperature (HMR3200)-40 °C to +85 °C
Supply voltage6‑15 VDC
Magnetic field range±2 Gauss
Update rate (HMR3200)15 Hz
UART baud rate2400‑19200 bps
SPI pin 1 functionSCK – serial clock output

Source: Honeywell HMR3200/HMR3300 Digital Compass User Manual

All Honeywell HMR330 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the operating temperature range of the HMR3200 and HMR3300?

The HMR3200 operates from –40 °C to +85 °C, while the HMR3300 operates from –20 °C to +70 °C.

From: Honeywell HMR3200/HMR3300 Digital Compass User Manual

What supply voltage does the digital compass require?

It requires a single‑supply voltage of 6 V to 15 V DC.