Honeywell HMR3300 Manuals

ManualLib has 6 documents for the Honeywell HMR3300: 5 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 5

Key facts

Model
HMR3300
Documents
6
Languages
ZH · EN
Last added
2012-02-16

Start here

Honeywell HMR3200/HMR3300 Digital Compass User Manual

Honeywell HMR3200/HMR3300 Digital Compass User Manual

User Manual 3 pages · 104 KB · ZH

This manual describes the Honeywell HMR3200 and HMR3300 digital compass modules, which offer compact size (25 mm × 37 mm × 10 mm) and low weight (≈7 g). The devices measure magnetic field with a range of ±2 Gauss and provide tilt angle measurement up to ±60°.

The document includes electrical specifications, pin assignments, UART and SPI communication protocols, command formats, and information about the demo development kit that accompanies the modules. This manual is written in Chinese.

Read online

Honeywell HMR3300 specifications

Repeatability0.5°
Tilt angle measurement range±60°
Module size25 mm × 37 mm × 10 mm
Weight (HMR3200)7.25 g
Supply voltage6‑15 VDC
Operating temperature-40 °C to +85 °C
Maximum magnetic field strength±2 Gauss
Update rate (HMR3200)15 Hz
UART baud rate range2400‑19200 bps
UART frame format1 start, 8 data, 1 stop, no parity

Source: Honeywell HMR3200/HMR3300 Digital Compass User Manual

All Honeywell HMR3300 documents by type

Questions answered in these manuals

What supply voltage does the HMR3200/HMR3300 require?

The modules operate from a single 6‑15 VDC power source.

From: Honeywell HMR3200/HMR3300 Digital Compass User Manual

How is UART communication configured for the compass modules?

UART uses ASCII format with 1 start bit, 8 data bits, 1 stop bit, no parity, and selectable baud rates from 2400 to 19200 bps.

From: Honeywell HMR3200/HMR3300 Digital Compass User Manual

What is the operating temperature range of the HMR3200/HMR3300?

The modules operate from –40 °C to +85 °C.

From: Honeywell HMR3200/HMR3300 Digital Compass User Manual

How is the module powered?

It uses a single supply voltage of 6‑15 VDC.

From: Honeywell HMR3200/HMR3300 Digital Compass User Manual

What is the supply voltage range for the modules?

They operate from a single 6 VDC to 15 VDC power source.

From: Honeywell HMR3200/HMR3300 Digital Compass User Manual

What is the operating temperature range of the HMR3200/HMR3300?

The modules operate from –40 °C to +85 °C.