Key facts
- Brand
- Honeywell
- Model
- HMC1001
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2012-08-09
Start here

Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook
This document provides technical specifications and application information for Honeywell HMC1001, HMC1002, HMC1021, and HMC1022 linear magnetic field sensors. These devices utilize magnetoresistive technology to convert magnetic fields into differential voltage outputs, suitable for navigation, attitude reference, and traffic detection applications.
Read onlineHoneywell HMC1001 specifications
| Field Range | ±2 gauss (HMC1001/1002), ±6 gauss (HMC1021/1022) |
|---|---|
| Operating Temperature | -55 to 150 °C |
| Bridge Supply | 5 to 12 Volts (HMC1001/1002) |
| Bridge Resistance | 600 to 1200 ohm |
| Noise Density | 29 nV/√Hz at 1 Hz |
| Bandwidth | 5 MHz |
| Max. Exposed Field | 10000 gauss |
Source: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook
All Honeywell HMC1001 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What are the applications for these sensors?
They are used in compassing navigation systems, attitude reference, traffic detection, and medical devices.
From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook
Do these sensors require external coils?
No, they feature patented on-chip set/reset straps that eliminate the need for external coils.
From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook
What are the applications for these magnetic sensors?
They are used for compassing, navigation systems, attitude reference, traffic detection, and medical devices.
From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook(1)
What is the maximum exposed field without perming effect?
The sensors can withstand a maximum exposed field of 10,000 gauss without a perming effect on the zero reading.
From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook(1)