Honeywell HMC1021 Manuals

ManualLib has 2 documents for the Honeywell HMC1021: 2 datasheets. Every file can be read online or downloaded as a PDF for free.

Datasheet 2

Key facts

Model
HMC1021
Industry
Industrial
Documents
2
Languages
EN
Last added
2012-08-09

Start here

Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook

Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook

Datasheet 15 pages · 230 KB · EN

This document provides technical specifications and application information for Honeywell HMC1001, HMC1002, HMC1021, and HMC1022 linear magnetic field sensors. These devices utilize magnetoresistive technology to convert magnetic fields into differential voltage outputs, suitable for navigation, attitude reference, and traffic detection applications.

Read online

Honeywell HMC1021 specifications

Field Range±2 gauss (HMC1001/1002), ±6 gauss (HMC1021/1022)
Operating Temperature-55 to 150 °C
Bridge Supply5 to 12 Volts (HMC1001/1002)
Bridge Resistance600 to 1200 ohm
Noise Density29 nV/√Hz at 1 Hz
Bandwidth5 MHz
Max. Exposed Field10000 gauss

Source: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook

All Honeywell HMC1021 documents by type

Questions answered in these manuals

What are the applications for these sensors?

They are used in compassing navigation systems, attitude reference, traffic detection, and medical devices.

From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook

Do these sensors require external coils?

No, they feature patented on-chip set/reset straps that eliminate the need for external coils.

From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook

What are the applications for these magnetic sensors?

They are used for compassing, navigation systems, attitude reference, traffic detection, and medical devices.

From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook(1)

What is the maximum exposed field without perming effect?

The sensors can withstand a maximum exposed field of 10,000 gauss without a perming effect on the zero reading.

From: Honeywell 1- 2-Axis Magnetic Sensors HMC1001 1002 HMC1021 1022 handbook(1)