WJ200 Series Inverter Quick Reference Guide
The Quick Reference Guide for the Hitachi WJ200 series inverters presents essential data for installation, wiring, and safety. It includes UL cautions, warnings, terminal screw sizes, and recommended wire gauges for each model variant.
The document also lists fuse requirements, detailed inverter specifications such as input/output ratings, rated capacity, starting torque, and weight. Safety sections cover safe‑disable functions, proof‑test intervals, and recommended external safety devices.
| Rated input voltage (single‑phase) | 200 V‑15% to 240 V +10% |
|---|---|
| Rated output voltage (three‑phase) | 200 V to 240 V (proportional to input) |
| Rated capacity (kVA) for VT 0.4 model | 0.4 kVA |
| Maximum surrounding air temperature | 50 °C |
Use 60/75 °C copper wire only for WJ200‑001L models.
The inverter can operate up to a surrounding air temperature of 50 °C.
A UL listed cartridge fuse rated 10 A with an AIC of 200 kA is required.