Dell PowerVault NX3600/NX3610 NAS Appliance Deployment Guide
This guide explains how to deploy Dell PowerVault NX3600 and NX3610 NAS appliances in a FluidFS solution with PowerVault MD32x0i and MD36x0i iSCSI storage arrays. It covers supported hardware and software, switch topologies, cabling, and management station preparation.
The document also describes running NAS IDU, configuring MD storage with disk groups and virtual disks, and using the NAS Manager Configuration Wizard for DNS, NTP, SMTP, SNMP, file system setup, Active Directory, CIFS, NFS, and client VIPs.
Dell PowerVault NX3600 specifications
| NX3600 network speed | 1 Gb |
|---|---|
| NX3610 network speed | 10 Gb |
| Supported NAS appliances for NX3600 | 1 |
| Supported NAS appliances for NX3610 | 2 |
| Supported MD storage arrays for NX3600 | MD3200i, MD3220i |
| Supported MD storage arrays for NX3610 | MD3600i, MD3620i, MD3660i |
| Cabling for 1 Gb | Cat 5E or higher |
| Cabling for 10 Gb | Cat 6A or higher |
| Jumbo frame MTU | 9216 |
| Dedicated SAN High-Availability switch count | 4 |
| All-in-one Non-Redundant switch count | 1 |
Source: Dell PowerVault NX3600/NX3610 NAS Appliance Deployment Guide
All Dell PowerVault NX3600 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
Which Dell NAS appliances are covered by this deployment guide?
The guide covers the Dell PowerVault NX3600 and NX3610 NAS appliances used with PowerVault MD32x0i and MD36x0i iSCSI deployments.
From: Dell PowerVault NX3600/NX3610 NAS Appliance Deployment Guide
What switch topology is recommended for the NX3600/NX3610?
The Dedicated SAN High Availability topology is recommended because it separates SAN and LAN/client traffic and uses redundant switches.
From: Dell PowerVault NX3600/NX3610 NAS Appliance Deployment Guide
Which Dell NAS devices are covered by this deployment guide?
The guide covers Dell PowerVault NX3600 and NX3610 NAS devices used with PowerVault MD32x0i and MD36x0i iSCSI storage arrays.
What software is required on the management station?
MD Storage Manager (MDSM) and NAS IDU must be installed on the management station.
What software is required to deploy the solution?
The deployment requires MD Storage Manager (MDSM) and NAS IDU installed on the management station.
From: Dell PowerVault NX3600/NX3610 NAS Appliance Deployment Guide
What MTU size is required for Dell PowerConnect switches?
Dell PowerConnect switches must be configured with an MTU size of 9216 or greater to accept frames of size 9000 MTU.
From: Dell PowerVault NX3600/NX3610 NAS Appliance Deployment Guide