IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) Interface Module User Manual
This document provides detailed instructions for installing, wiring, configuring, and troubleshooting the Siemens IM 155-6 PN/2 HF interface module. It covers technical specifications, diagnostic procedures, interrupt handling, and compatibility with SIMATIC ET 200SP systems. The manual is intended for qualified personnel familiar with industrial automation systems and Siemens products.
The module supports PROFINET IO communication, real-time communication, and various redundancy features including MRP and system redundancy S2. It includes detailed sections on parameter settings, address space, error messages, and diagnostic tools for troubleshooting system issues. This manual is written in Chinese.
Siemens IM 155-6 PN specifications
| BusAdapter | BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC |
|---|---|
| Protocol | PROFINET IO Device |
| Transmission Mode | PROFINET, 100 Mbit/s, full-duplex (100BASE-TX) |
| IRT Support | Yes, with cycle times 125 µs to 4 ms |
| PROFIenergy | Yes |
| Priority Startup | Yes |
| Shared Device Support | Yes, up to 4 IO controllers |
| Redundancy Mode | MRP |
Source: IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) Interface Module User Manual
All Siemens IM 155-6 PN documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the maximum number of IO controllers in shared device mode?
Up to 4 IO controllers can be connected in shared device mode.
From: IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) Interface Module User Manual
What is the transmission mode and speed?
The module supports PROFINET with 100 Mbit/s, full-duplex (100BASE-TX) transmission.
From: IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) Interface Module User Manual
What is the supply voltage for this interface module?
The module operates with a supply voltage of 24 V DC.
From: IM 155-6 PN ST interface module (6ES7155-6AU00-0BN0) manual
What is the maximum number of I/O modules supported in this configuration?
The system supports a maximum of 32 I/O modules.
From: IM 155-6 PN ST interface module (6ES7155-6AU00-0BN0) manual
What is the purpose of this manual?
This manual supplements the ET 200SP distributed I/O system manual and supports you in commissioning the ET 200SP distributed I/O system.
Who is qualified to operate this product?
The product may be operated only by personnel who are qualified for the specific task based on their training and experience.