User Manual 3

Key facts

Brand
Siemens
Model
6SE70
Category
Motor
Industry
Industrial
Documents
3
Languages
ZH
Last added
2026-10-06

Start here

Siemens 6SE7085-0QX60 SIMOVERT MASTERDRIVES Vector Control Usage Guide

Siemens 6SE7085-0QX60 SIMOVERT MASTERDRIVES Vector Control Usage Guide

User Manual 505 pages · 8.2 MB · ZH

The document provides a detailed system description of the SIMOVERT MASTERDRIVES vector‑control drive, including hardware layout, dimensions and environmental ratings. It also presents configuration and wiring examples for various installation types such as water‑cooled and single‑unit setups.

Further sections cover EMC design guidelines, function blocks, parameter settings, step‑by‑step parameter configuration, and communication interfaces (USS, PROFIBUS, CAN). The guide is intended for the V3.3 software version and includes diagnostic and troubleshooting information. This manual is written in Chinese.

Read online

Siemens 6SE70 specifications

Power range0.55 kW to 2300 kW
Input voltage380 V to 690 V
Power range (alternative range)0.55 kW to 18.5 kW

Source: Siemens 6SE70 Vector Control Drive Technical Manual

All Siemens 6SE70 documents by type

User Manual 3

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What power range does the 6SE70 drive support?

The 6SE70 drive supports power ratings from 0.55 kW up to 2300 kW.

From: Siemens 6SE70 Vector Control Drive Technical Manual

What input voltage options are available for the 6SE70?

It can operate on input voltages of 380 V, 500 V, or 690 V.

From: Siemens 6SE70 Vector Control Drive Technical Manual

Which software version does this guide apply to?

The guide is intended for devices running software version V3.3.

From: Siemens 6SE7085-0QX60 Vector Control Usage Guide (Volume 2)

What does control word bit 0 represent?

Control word bit 0 is the start/stop command (ON/OFF) for the inverter.

From: Siemens 6SE7085-0QX60 Vector Control Usage Guide (Volume 2)

Which software version does this guide apply to?

It applies only to devices running software version V3.3.

From: Siemens 6SE7085-0QX60 SIMOVERT MASTERDRIVES Vector Control Usage Guide

What is the maximum allowed working pressure for water‑cooled MASTERDRIVES?

The working pressure must not exceed 1 bar.

From: Siemens 6SE7085-0QX60 SIMOVERT MASTERDRIVES Vector Control Usage Guide