Key facts
- Brand
- Siemens
- Model
- SINAMICS S120
- Category
- Industrial Robot
- Industry
- Industrial
- Documents
- 16
- Languages
- FR · ZH · EN
- Last added
- 2026-10-21
Start here

Siemens SINAMICS S120 Startdrive Commissioning Manual
This document serves as the commissioning manual for the SINAMICS S120 Startdrive system, specifically designed for firmware version 5.1 and Startdrive V15. It is intended for machine manufacturers, commissioning personnel, and maintenance staff who operate the drive system.
The manual covers essential topics including the startup commissioning process, the use of the Startdrive tool, basic system information, diagnostic methods, and an appendix. It outlines the scope of application, target user groups, and relevant technical standards and directives applicable to the product. This manual is written in Chinese.
Siemens SINAMICS S120 specifications
| Control Unit (Single Axis) | CU310 DP or CU310 PN |
|---|---|
| Power Module Voltage (Multi-axis) | 540V or 600V DC |
| Max Servo Axes (Speed Control) | 6 axes |
| Max Servo Axes (Position Control) | 4 axes |
| Max Vector Axes (Speed Control) | 4 axes |
| Max Vector Axes (Position Control) | 2 axes |
Source: Siemens SINAMICS S120 Drive Application Basics Manual
All Siemens SINAMICS S120 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Siemens SINAMICS S120 Commissioning Manual 274 p
- Siemens SINAMICS S120 Startdrive Commissioning Manual 462 p
- Siemens SINAMICS S120 Synchronous Motors 1FK7 Configuration Manual 252 p
- Siemens SINAMICS S120 Synchronous Motor 1FK7 Configuration Manual 252 p
- Siemens SINAMICS S120 Startdrive Commissioning Manual 384 p
- Siemens SINAMICS S120 Drive Application Basics Manual 117 p
- Siemens SINAMICS S120 Starter Getting Started Guide 62 p
- Siemens SINAMICS S120CM User Manual 4 p
- Siemens SINUMERIK 802D sl SINAMICS S120 Product Manual 85 p
- Siemens SINAMICS S120 1FK7 Configuration Manual 126 p
How to use the product for one specific task, with worked examples.
Disassembly, diagnostics and part numbers, for repair.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What firmware version is this manual valid for?
This manual is valid for firmware version 4.5 (IH1).
Who is the target audience for this documentation?
The documentation addresses machine manufacturers and commissioning/maintenance personnel using the SINAMICS drive system.
What firmware and Startdrive versions does this manual cover?
This manual is applicable for Firmware Version 5.1 and Startdrive V15.
Who are the intended users of this document?
This document is for machine manufacturers, commissioning personnel, and maintenance staff who use SINAMICS drive systems.
What safety symbol indicates that death or severe personal injury will occur if precautions are not taken?
The danger symbol indicates that death or severe personal injury will result if proper precautions are not taken.
From: Siemens SINAMICS S120 Synchronous Motors 1FK7 Configuration Manual
What is the maximum surface temperature the motors can reach?
The motors can have surface temperatures of over +100 °C.
From: Siemens SINAMICS S120 Synchronous Motors 1FK7 Configuration Manual