INVT DA180 Error Codes

109 codes from pages 253–314 of the manual

This is the list of error, fault codes the INVT manual gives for the DA180 AC servo drive. Find your code below and open it for what the manual says about its causes and what to do.

Error codes from p. 253

Fault codes from p. 257

CodeWhat it meansPage
Er01-0 IGBT fault p. 257
Er01-1 Brake pipe fault (for models of 7.5kW or above) p. 257
Er02-0 Encoder fault--Encoder offline p. 257
Er02-1 Encoder fault--Encoder feedback deviation too large p. 257
Er02-2 Encoder fault--Parity error p. 257
Er02-3 Encoder fault--CRC error p. 257
Er02-4 Encoder fault--Frame error p. 257
Er02-5 Encoder fault--Short frame error p. 257
Er02-6 Encoder fault--Encoder timeout p. 257
Er02-7 Encoder fault--Second-encoder timeout p. 257
Er02-8 Encoder fault--Encoder battery low-voltage alarm p. 257
Er02-9 Encoder fault--Encoder battery undervoltage fault p. 257
Er02-a Encoder fault--Encoder overheating p. 257
Er02-b Encoder fault--Encoder EEPROM writing error p. 257
Er02-c Encoder fault--No data in encoder EEPROM p. 257
Er02-d Encoder fault--Encoder EEPROM data check error p. 257
Er03-0 Current sensor fault--Phase-U current sensor fault p. 257
Er03-1 Current sensor fault--Phase-V current sensor fault p. 257
Er03-2 Current sensor fault--Phase-W current sensor fault p. 257
Er04-0 System initialization fault p. 257
Er05-1 Setting fault--Motor model not exist p. 257
Er05-2 Setting fault--Motor and drive model not match p. 257
Er05-3 Setting fault-Incorrect software limits p. 258
Er05-4 Setting fault-Incorrect homing mode p. 258
Er05-5 Setting fault-PTP-control travel overflow p. 258
Er07-0 Regeneration discharge overload fault p. 258
Er08-0 AI overvoltage fault—AI 1 p. 258
Er08-1 AI overvoltage fault—AI 2 p. 258
Er09-0 EEPROM fault—Read/write error p. 258
Er09-1 EEPROM fault—Data check error p. 258
Er10-0 Hardware fault-FPGA fault p. 258
Er10-1 Communication card fault p. 258
Er10-2 Hardware fault—Ground short-connection fault p. 258
Er10-3 Hardware fault—External input fault p. 258
Er10-4 Hardware fault—Emergency stop fault p. 258
Er10-5 Hardware fault-RS485 communication fault p. 258
Er11-0 Software fault-Motor control task re-entry p. 258
Er11-1 Software fault-Periodic task re-entry p. 258
Er11-2 Software fault—Illegal operation p. 258
Er12-0 I/O fault—Duplicate digital input assignment p. 258
Er12-1 I/O fault—Duplicate AI assignment p. 258
Er12-2 I/O fault—Pulse input frequency too high p. 258
Er13-0 Main circuit overvoltage p. 258
Er13-1 Main circuit undervoltage p. 258
Er17-0 Drive overload p. 258
Er18-0 Motor overload p. 258
Er18-1 Motor overtemperature p. 258
Er19-0 Speed fault—Overspeed p. 258
Er19-1 Speed fault—CCW overspeed p. 258
Er19-2 Speed fault—CW overspeed p. 258
Er19-3 Speed fault—Overspeed parameter set incorrectly p. 258
Er20-0 Speed deviation fault p. 258
Er21-0 Position overtravel—CCW p. 258
Er21-1 Position overtravel—CW p. 258
Er22-0 Position deviation fault p. 258
Er22-1 Hybrid control deviation too large p. 258
Er22-2 Position increment overflow p. 259
Er22-3 CANopen fault—Synchronization signal timeout p. 275
Er22-4 CANopen fault—Full position command buffer p. 275
Er23-0 Drive overtemperature p. 274
Er25-4 Application fault—Encoder offset angle test timeout p. 274
Er25-5 Application fault—Encoder offset angle test failed p. 274
Er25-6 Application fault—Homing offside p. 274
Er25-7 Application fault—Inertia identifying failed p. 274
Er26-0 CANopen fault—CANopen offline p. 275
Er26-1 CANopen fault—SDO index not exist p. 275
Er26-2 CANopen fault—SDO sub-index not exist p. 259
Er26-3 CANopen fault—Incorrect SDO data length p. 259
Er26-4 CANopen fault—SDO data out of range p. 259
Er26-5 CANopen fault—Modification not allowed for read-only p. 259
Er26-6 CANopen fault—Incorrect PDO mapping length p. 259
Er26-7 CANopen fault—PDO mapping data not exist p. 259
Er26-8 CANopen fault—PDO modification not allowed in operational state p. 259
Er26-9 CANopen fault—PDO mapping not allowed p. 259
Er26-a CANopen fault—Synchronization signal too fast p. 259
Er26-b CANopen fault—Receiving fault p. 277
Er26-c CANopen fault—Sending fault p. 277
Er26-d CANopen fault—Duplicate synchronization signal p. 277
Er26-e CANopen fault—Bus load ratio too high p. 277
Er26-f CANopen fault—Incorrect parameter modification status p. 277
Er01-5 IPM fault p. 265
Er10-6 Hardware fault--AC power phase loss p. 270
Er10-7 Hardware fault--Fan fault p. 270
Er10-8 Hardware fault--Regenerative transistor fault p. 270
Er10-9 Hardware fault--STO phase loss p. 270
Er10-a Hardware fault--STO DPIN1 fault p. 270
Er10-b Hardware fault--STO DPIN2 fault p. 270
Er17-1 Drive overload 2 p. 272
Er19-4 Overspeed fault—Motor runaway p. 272
Er25-8 Application fault– Magnetic pole check failed p. 275
Er25-9 Application fault– Overtail/overspeed in confirmation of magnetic pole check p. 275
Er25-a Application fault– Out-of-range in magnetic pole check p. 275
R0.99 Fault code p. 307
R3.00 Fault code p. 307
Er01-2 Phase-U IGBT fault p. 310
Er01-3 Phase-V IGBT fault p. 310
Er01-4 Phase-W IGBT fault p. 310
Er05-0 Setting fault--Drive model not exist p. 311
Er05-6 Setting fault--Incorrect power module settings p. 311
Er06-0 Brake fault p. 311
Er24-8 EtherCAT fault—Initialization fault p. 313
Er24-9 EtherCAT fault—EEPROM fault p. 313
Er24-a EtherCAT fault—DC Sync0 signal exception p. 313
Er24-b EtherCAT fault—Disconnection p. 313
Er24-c EtherCAT fault—PDO data lost p. 313

Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with INVT. Found a mistake? Report an error.