Application fault—Encoder offset angle test failed occurs when there is great fluctuation in current feedback during encoder offset angle testing on the INVT DA180 drive. The manual's first action is: “Reduce the setting of P4.53 and then carry out the test after repower-on.”
- Model
- INVT DA180
- Display shows
- Application fault—Encoder offset angle test failed (Er25-5)
- Type
- Fault code
- Source
- Manual p. 259
What Er25-5 means
Application fault—Encoder offset angle test failed p. 274
Common causes
- There is great fluctuation in current feedback in the encoder offset angle test. p. 274
What to do
- Reduce the setting of P4.53 and then carry out the test after repower-on. p. 274
If Er25-5 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.
This page summarises what the manufacturer’s manual says about Er25-5; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.