INVT DA180 Error Er03-0: Current sensor fault--Phase-U current sensor fault

AC servo drive · taken from the manufacturer’s manual, pages cited

Fault codeEr03-0

The current sensor for Phase-U has failed due to an abnormality in the sensor or detection circuit. The manual's first action is: “7300-0300h”

Model
INVT DA180
Display shows
Current sensor fault--Phase-U current sensor fault (Er03-0)
Type
Fault code
Source
Manual p. 257

What Er03-0 means

Current sensor fault--Phase-U current sensor fault p. 257

Common causes

  • Current sensor fault--Phase-U current sensor fault p. 257
  • 1. The current sensor or detection circuit is abnormal. p. 257

What to do

  1. 7300-0300h p. 257
  2. Repower on the motor shaft in static state. If the fault is reported p. 257

If Er03-0 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er03-0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.