INVT DA180 Error Er13-0: Main circuit overvoltage

AC servo drive · taken from the manufacturer’s manual, pages cited

Fault codeEr13-0

Main circuit overvoltage occurs when the DC voltage of the main circuit is higher than set, possibly from grid voltage or internal circuit damage. The manual's first action is: “3110-0D00h”

Model
INVT DA180
Display shows
Main circuit overvoltage (Er13-0)
Type
Fault code
Source
Manual p. 258

What Er13-0 means

Main circuit overvoltage p. 258

Common causes

  • 2. There is damage to the internal pulse frequency detection circuit of the drive. p. 258
  • The DC voltage of the drive main circuit is higher than the specified voltage. p. 258
  • 1. The grid voltage is too high. p. 258
  • 2. No brake resistor or pipe is connected during braking or the brake resistor is damaged. p. 258
  • 3. The DEC time in the stop process is too short. p. 258
  • 4. The internal DC voltage detection circuit of the drive is damaged. p. 258

What to do

  1. 3110-0D00h p. 258
  2. 1. Ensure the grid input voltage is within the allowed range. 2. Ensure the internal brake resistor is not loose or damaged. Ensure the external brake resistor is not damaged. 3. Increase the DEC time. 4. Check R0.07 when the drive is disabled. If it is abnormal and does not match the grid input voltage, replace the drive. p. 258

If Er13-0 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er13-0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.