Fault codeEr02-7
A second encoder timed out, likely due to an unconnected encoder or loose plug contact. The manual's first action is: “7300-0207h”
- Model
- INVT DA180
- Display shows
- Encoder fault--Second-encoder timeout (Er02-7)
- Type
- Fault code
- Source
- Manual p. 257
What Er02-7 means
Encoder fault--Second-encoder timeout p. 257
Common causes
- Encoder fault--Second-encoder timeout p. 257
- 1. The encoder is not connected. p. 257
- 2. The encoder plug contact is loose. p. 257
- 3. One of encoder signal cables U, V, W, A, B, and Z is disconnected. p. 257
- 4. Encoder phases A and B are reverse. p. 257
- 5. Eliminate the conditions that disturb encoder cables. Route encoder cables and motor cables separately. p. 257
What to do
- 7300-0207h p. 257
- 1. Connect the encoder according to the correct wiring method. p. 257
- 2. Ensure the encoder plug contact is proper. p. 257
- 3. Replace the encoder cable. p. 257
- 4. Ensure the encoder power voltage is proper. p. 257
- 5. Eliminate the conditions that disturb encoder cables. Route encoder cables and motor cables separately. p. 257
If Er02-7 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.
This page summarises what the manufacturer’s manual says about Er02-7; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.