INVT DA180 Error Er26-d: CANopen fault—Duplicate synchronization signal

AC servo drive · taken from the manufacturer’s manual, pages cited

Fault codeEr26-d

CANopen fault—Duplicate synchronization signal happens when multiple slave nodes generate synchronization signals in the network. The manual's first action is: “Modify configuration so that there is only one synchronization signal generation source in the entire communication network.”

Model
INVT DA180
Display shows
CANopen fault—Duplicate synchronization signal (Er26-d)
Type
Fault code
Source
Manual p. 259

What Er26-d means

CANopen fault—Duplicate synchronization signal p. 277

Common causes

  • In the case where a slave node is configured to generate synchronization signals, synchronization signals are received. p. 277

What to do

  1. Modify configuration so that there is only one synchronization signal generation source in the entire communication network. p. 277

If Er26-d is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er26-d; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.