Fault codeEr09-1
EEPROM data check error occurred because read data differs from written data or the DSP version was updated. The manual's first action is: “5530-0901h”
- Model
- INVT DA180
- Display shows
- EEPROM fault—Data check error (Er09-1)
- Type
- Fault code
- Source
- Manual p. 258
What Er09-1 means
EEPROM fault—Data check error p. 258
Common causes
- 1. The data read from EEPROM during power-on is different from the data that is written. 2. The driver DSP version is updated. p. 258
- • p. 258
What to do
- 5530-0901h p. 258
- 1. Set all parameters again. 2. If the fault occurs repeatedly, replace the drive. p. 258
If Er09-1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.
This page summarises what the manufacturer’s manual says about Er09-1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.