INVT DA180 Error Er09-1: EEPROM fault—Data check error

AC servo drive · taken from the manufacturer’s manual, pages cited

Fault codeEr09-1

EEPROM data check error occurred because read data differs from written data or the DSP version was updated. The manual's first action is: “5530-0901h”

Model
INVT DA180
Display shows
EEPROM fault—Data check error (Er09-1)
Type
Fault code
Source
Manual p. 258

What Er09-1 means

EEPROM fault—Data check error p. 258

Common causes

  • 1. The data read from EEPROM during power-on is different from the data that is written. 2. The driver DSP version is updated. p. 258
  • • p. 258

What to do

  1. 5530-0901h p. 258
  2. 1. Set all parameters again. 2. If the fault occurs repeatedly, replace the drive. p. 258

If Er09-1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er09-1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.