INVT DA180 Error Er02-2: Encoder fault--Parity error

AC servo drive · taken from the manufacturer’s manual, pages cited

Fault codeEr02-2

A parity error occurred in the encoder data, possibly due to a disconnected encoder or loose plug contact. The manual's first action is: “7300-0202h”

Model
INVT DA180
Display shows
Encoder fault--Parity error (Er02-2)
Type
Fault code
Source
Manual p. 257

What Er02-2 means

Encoder fault--Parity error p. 257

Common causes

  • Encoder fault--Parity error p. 257
  • 1. The encoder is not connected. p. 257
  • 2. The encoder plug contact is loose. p. 257
  • 3. One of encoder signal cables U, V, W, A, B, and Z is disconnected. p. 257
  • 4. Encoder phases A and B are reverse. p. 257
  • 5. Eliminate the conditions that disturb encoder cables. Route encoder cables and motor cables separately. p. 257

What to do

  1. 7300-0202h p. 257
  2. 1. Connect the encoder according to the correct wiring method. p. 257
  3. 2. Ensure the encoder plug contact is proper. p. 257
  4. 3. Replace the encoder cable. p. 257
  5. 4. Ensure the encoder power voltage is proper. p. 257
  6. 5. Eliminate the conditions that disturb encoder cables. Route encoder cables and motor cables separately. p. 257

If Er02-2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er02-2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.