INVT DA180 Error Er05-2: Setting fault--Motor and drive model not match

AC servo drive · taken from the manufacturer’s manual, pages cited

Fault codeEr05-2

The motor and drive models do not match, as P0.00 is set incorrectly. The manual's first action is: “FF01-0502h”

Model
INVT DA180
Display shows
Setting fault--Motor and drive model not match (Er05-2)
Type
Fault code
Source
Manual p. 257

What Er05-2 means

Setting fault--Motor and drive model not match p. 257

Common causes

  • Setting fault--Motor and drive model not match p. 257
  • P0.00 is set incorrectly. p. 257
  • • p. 257

What to do

  1. FF01-0502h p. 257
  2. Set P0.35 and P0.36 correctly. p. 257

If Er05-2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er05-2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.