Fault codeEr01-5

IPM fault occurs when the drive’s actual output current exceeds its specified limit, requiring cable check and possible replacement. The manual lists no action for this code.

Model
INVT DA180
Display shows
IPM fault (Er01-5)
Type
Fault code
Source
Manual p. 265

What Er01-5 means

IPM fault p. 265

Common causes

  • The drive actual output current exceeds the specified value. p. 265
  • 1. Remove the motor cables and then enable the drive. If the fault persists, replace the drive. p. 265
  • 2. Ensure the motor cables and wiring are in good conditions. p. 265
  • 3. Reduce the settings of P0.10 and P0.11 to reduce the maximum output torque. p. 265
  • 4. Increase the ACC/DEC time. p. 265
  • 5. Replace the drive with a new one with greater power. p. 265
  • 6. Replace the motor. p. 265

If Er01-5 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er01-5; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.