INVT DA180 Error Er10-3: Hardware fault—External input fault

AC servo drive · taken from the manufacturer’s manual, pages cited

Fault codeEr10-3

An external input fault occurred when a configured digital terminal acted as an external fault input. The manual's first action is: “5544-0A03h”

Model
INVT DA180
Display shows
Hardware fault—External input fault (Er10-3)
Type
Fault code
Source
Manual p. 258

What Er10-3 means

Hardware fault—External input fault p. 258

Common causes

  • This fault occurs when the digital terminal configured with the external fault input function acts. p. 258
  • • p. 258

What to do

  1. 5544-0A03h p. 258
  2. 1. Clear the external fault input. 2. Repower on the drive. p. 258

If Er10-3 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact INVT service.

This page summarises what the manufacturer’s manual says about Er10-3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with INVT. Found a mistake? Report an error.