This is the list of fault, error, warning codes the Inovance manual gives for the ISMH/ISMV series servo motor. Find your code below and open it for what the manual says about its causes and what to do.
Fault codes from p. 184
| Code | Display message | What it means | Page |
|---|---|---|---|
Er.101 |
EEPROM parameter abnormality | EEPROM参数异常 | p. 184 |
Er.102 |
Programmable logic configuration fault | 可编程逻辑配置故障 | p. 184 |
Er.105 |
System abnormality | 系统异常 | p. 184 |
Er.107 |
Product model selection fault | 产品型号选择故障 | p. 184 |
Er.108 |
Parameter storage fault | 参数存储故障 | p. 184 |
Er.110 |
Frequency division pulse output setting fault | 分频脉冲输出设定故障 | p. 184 |
Er.120 |
Product matching fault | 产品匹配故障 | p. 184 |
Er.121 |
Servo ON command invalid fault | 伺服ON指令无效故障 | p. 184 |
Er.130 |
DI assignment fault | DI分配故障 | p. 184 |
Er.131 |
DO assignment fault | DO分配故障 | p. 184 |
Er.140 |
AI setting fault | AI设定故障 | p. 188 |
Er.200 |
Drive overcurrent 1 | 驱动器过流1 | p. 189 |
Er.201 |
Drive overcurrent 2 | 驱动器过流2 | p. 189 |
Er.400 |
Overvoltage | 过电压 | p. 189 |
Er.420 |
Power line missing phase | 电源线缺相 | p. 190 |
Er.500 |
Overspeed | 过速 | p. 190 |
Er.600 |
Inertia identification failure fault | 惯量辨识失败故障 | p. 190 |
Er.620 |
Motor overload | 电机过载 | p. 190 |
Er.650 |
Heatsink overheating | 散热器过热 | p. 190 |
Er.740 |
Encoder Interference Fault 1 | 编码器干扰故障1 | p. 191 |
Er.741 |
Encoder Interference Fault 2 | 编码器干扰故障2 | p. 191 |
Er.831 |
AD Sampling Fault 1 | AD采样故障1 | p. 191 |
Er.832 |
AD Sampling Fault 2 | AD采样故障2 | p. 191 |
Er.833 |
Current Sampling Fault | 电流采样故障 | p. 191 |
Er.850 |
Encoder Angle Fault | 编码器角度故障 | p. 191 |
Er.A21 |
Programmable Logic Fault | 可编程逻辑故障 | p. 191 |
ER.234 |
AC220V (AC380) 用伺服驱动器,检出了直流母线在420V (760V) 以上;或电源电压高于输入电压范围; | p. 189 | |
Er.602 |
Angle Identification Fault | 角度辨识故障 | p. 190 |
Er.834 |
AI Channel Overvoltage Fault | AI通道电压过高故障 | p. 191 |
Error codes from p. 184
| Code | Display message | What it means | Page |
|---|---|---|---|
Er.135 |
Motor encoder EEPROM parameter abnormality | 电机编码器EEPROM参数异常 | p. 184 |
Er.136 |
Motor encoder EEPROM data checksum error | 电机编码器EEPROM中数据校验错误 | p. 184 |
Er.210 |
Servo power-on self-test detected output ground short circuit fault | 伺服上电自检发现输出对地短路故障 | p. 189 |
Er.410 |
Undervoltage | 欠电压 | p. 190 |
Er.510 |
Frequency division pulse output overspeed | 分频脉冲输出过速 | p. 190 |
Er.610 |
Drive overload | 驱动器过载 | p. 190 |
Er.900 |
Position Deviation Too Large | 位置偏差过大 | p. 186 |
Er.922 |
External Regeneration Dump Resistor Too Small | 外接再生泄放电阻过小 | p. 192 |
Er.941 |
Parameter Change Requires Power Cycle | 需要新接通电源的参数变更 | p. 186 |
Er.A35 |
Z Signal Lost | Z信号丢失 | p. 191 |
Warning codes from p. 186
| Code | Display message | What it means | Page |
|---|---|---|---|
Er.909 |
Motor Overload | 电机过载 | p. 186 |
Er.910 |
Drive Overload | 驱动器过载 | p. 186 |
Er.942 |
Frequent EEPROM Write Warning | 写EEPROM频繁警告 | p. 186 |
Er.950 |
Travel Limit Warning | 超程警告提示 | p. 186 |
Er.960 |
Absolute Encoder Angle Initialization Warning | 绝对值编码器角度初始化警告 | p. 192 |
Er.971 |
Undervoltage Warning | 欠电压警告 | p. 186 |
Er.981 |
Heatsink Overheat Warning | 散热器过热警告 | p. 186 |
Er.990 |
Input Phase Loss Warning | 输入缺相警告 | p. 186 |
Er.991 |
Communication Module Self‑Test Failure Warning | 通信模块自检失败警告 | p. 186 |
Er.992 |
Communication Module Communication Error Warning | 通信模块通信异常警告 | p. 186 |
Er.b00 |
伺服电机的UVW接线不正确 | p. 191 |
Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.