Inovance ISMH/ISMV series Error Er.510: Frequency division pulse output overspeed

Servo motor · taken from the manufacturer’s manual, pages cited

Error codeEr.510

Frequency division pulse output overspeed means the motor speed exceeds the upper limit set for the encoder division pulse count or the encoder division output pulse frequency exceeds the hardware limit (1.6 MHz). The manual's first action is: “Calculate the division output pulse frequency corresponding to the encoder division setting at the operating speed to verify if it exceeds the limit. Change the division output setting function code so that across the entire servo speed range, the division output pulse frequency does not exceed the limit.”

Model
Inovance ISMH/ISMV series
Display shows
Frequency division pulse output overspeed (Er.510)
Type
Error code
Source
Manual p. 185

What Er.510 means

Frequency division pulse output overspeed p. 190

Common causes

  • Motor speed exceeds the upper limit set for the encoder division pulse count p. 190
  • Encoder division output pulse frequency exceeds the hardware limit (1.6 MHz) p. 190

What to do

  1. Calculate the division output pulse frequency corresponding to the encoder division setting at the operating speed to verify if it exceeds the limit. Change the division output setting function code so that across the entire servo speed range, the division output pulse frequency does not exceed the limit. p. 190

Before you service the product, read the safety instructions in the manual p. 186.

If Er.510 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.510; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.