Inovance ISMH/ISMV series Error Er.b00

Servo motor · taken from the manufacturer’s manual, pages cited

Warning codeEr.b00

Er.b00 means the servo motor UVW wiring is incorrect, or the position command pulse frequency is high, or the position command acceleration is too large. The manual's first action is: “Check if the servo drive gain is too low; increase gain (H08-02)”

Model
Inovance ISMH/ISMV series
Display shows
Er.b00
Type
Warning code
Source
Manual p. 191

What Er.b00 means

Servo motor UVW wiring incorrect p. 191

Common causes

  • Servo motor UVW wiring incorrect p. 191
  • Position command pulse frequency is high p. 191
  • Position command acceleration too large p. 191
  • Given operating conditions, the position deviation warning value (H0a-11) may be inappropriate p. 191
  • Servo drive fault p. 191

What to do

  1. Check if the servo drive gain is too low; increase gain (H08-02) p. 191
  2. Try reducing the command frequency before running; lower position command frequency, command acceleration, or adjust the electronic gear ratio p. 191
  3. After lowering command acceleration, run again; add position command acceleration/deceleration time parameters or other smoothing functions (H05-06) p. 191
  4. Verify that the position deviation warning value (H0a-11) is appropriate; set H0a-11 correctly p. 191
  5. Determine the ratio of function codes H05-11/H05-10; set the ratio within an appropriate range p. 191

Before you service the product, read the safety instructions in the manual p. 186.

If Er.b00 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.b00; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.