Inovance ISMH/ISMV series Error Er.210: Servo power-on self-test detected output ground short circuit fault

Servo motor · taken from the manufacturer’s manual, pages cited

Error codeEr.210

This code indicates servo power-on self-test detected output ground short circuit fault, which can be caused by self-test on power-up detecting servo motor power cable ground short circuit, UVW phase order error, or encoder model set incorrectly or wiring error. The manual's first action is: “Confirm UVW phase order”

Model
Inovance ISMH/ISMV series
Display shows
Er.210
Type
Error code
Source
Manual p. 185

What Er.210 means

Servo power-on self-test detected output ground short circuit fault p. 189

Common causes

  • Self-test on power-up detected servo motor power cable ground short circuit p. 189
  • UVW phase order error p. 189
  • Encoder model set incorrectly or wiring error p. 189

What to do

  1. Confirm UVW phase order p. 189
  2. Confirm encoder related information p. 189

Before you service the product, read the safety instructions in the manual p. 186.

If Er.210 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.210; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.