This code indicates AI setting fault, which can be caused by the same AI assigned to different command sources, AI resource assigned repeatedly in a certain control mode, or AI resources used in speed mode. The manual's first action is: “Change the related function code values”
- Model
- Inovance ISMH/ISMV series
- Display shows
- AI setting fault (Er.140)
- Type
- Fault code
- Source
- Manual p. 185
What Er.140 means
AI setting fault p. 188
Common causes
- The same AI assigned to different command sources p. 188
- In a certain control mode, the AI resource is assigned repeatedly (e.g., AI1 used both as torque control command source (H07-00) and as speed limit source (H07-17, H07-18)) p. 188
- In speed mode (or combined speed control mode), check H07-00, H07-01, H07-08 (effective when H07-07 set to 2/3), H07-17, H07-18 (effective when H07-17 set to 1) to determine if any AI resources are duplicated p. 188
- In position mode (or combined position control mode), check H06-13, H06-11, H07-08 (effective when H07-07 set to 2/3) to determine if any AI resources are duplicated p. 188
What to do
- Change the related function code values p. 188
Before you service the product, read the safety instructions in the manual p. 186.
If Er.140 is still not resolved
This page summarises what the manufacturer’s manual says about Er.140; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.