Inovance ISMH/ISMV series Error Er.105: System abnormality

Servo motor · taken from the manufacturer’s manual, pages cited

Fault codeEr.105

This code indicates system abnormality, which can be caused by abnormal data encountered during servo program selection judgment, EEPROM failure, or servo drive failure. The manual's first action is: “NO.1”

Model
Inovance ISMH/ISMV series
Display shows
System abnormality (Er.105)
Type
Fault code
Source
Manual p. 184

What Er.105 means

System abnormality p. 184

Common causes

  • Abnormal data encountered during servo program selection judgment; factory defaults need to be restored p. 184
  • 1. EEPROM failure p. 184
  • 2. Servo drive failure p. 184

What to do

  1. NO.1 p. 184
  2. Confirm according to the method for Er.101 p. 184
  3. If the fault persists after multiple power cycles, it may be that the servo drive has failed. p. 184
  4. Repair or replace the servo drive p. 184

Before you service the product, read the safety instructions in the manual p. 186.

If Er.105 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.105; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.