Fault codeEr.110

This code indicates frequency division pulse output setting fault, which occurs when the encoder division pulse count does not meet the set condition or range. The manual's first action is: “NO.1”

Model
Inovance ISMH/ISMV series
Display shows
Frequency division pulse output setting fault (Er.110)
Type
Fault code
Source
Manual p. 184

What Er.110 means

Frequency division pulse output setting fault p. 184

Common causes

  • Encoder division pulse count does not meet the set condition/range p. 184

What to do

  1. NO.1 p. 184
  2. Incremental encoder: the encoder division pulse count must not exceed the number of lines of the encoder; absolute encoder: the division pulse count must not exceed one quarter of its resolution p. 184
  3. Change the encoder division pulse count function code to meet the specified range p. 184

Before you service the product, read the safety instructions in the manual p. 186.

If Er.110 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.110; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.