Inovance ISMH/ISMV series Error Er.120: Product matching fault

Servo motor · taken from the manufacturer’s manual, pages cited

Fault codeEr.120

This code indicates product matching fault, which can be caused by motor and drive power rating mismatch, unsupported component type connected, or improper combination of products. The manual's first action is: “NO.1”

Model
Inovance ISMH/ISMV series
Display shows
Product matching fault (Er.120)
Type
Fault code
Source
Manual p. 184

What Er.120 means

Product matching fault p. 184

Common causes

  • Motor and drive power rating (rated voltage) mismatch, or unsupported component type (e.g., encoder) is connected p. 184
  • Improper combination of products, e.g., motor and drive power rating mismatch p. 184
  • Connected an encoder type not supported by the selected drive (e.g., A/A type drive does not support absolute encoder) p. 184

What to do

  1. NO.1 p. 184
  2. Check whether the motor's rated current is within the drive's current rating p. 184
  3. Refer to the user manual to confirm whether the selected drive type and its supported encoder types include this encoder p. 184
  4. Select the correct encoder type or replace with a different type of drive p. 184

Before you service the product, read the safety instructions in the manual p. 186.

If Er.120 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.120; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.