Inovance ISMH/ISMV series Error Er.600: Inertia identification failure fault

Servo motor · taken from the manufacturer’s manual, pages cited

Fault codeEr.600

Inertia identification failure fault means the inertia identification operation timed out due to excessive load torque or excessive load inertia. The manual's first action is: “Excessive load torque (e.g., motor stall) or excessive load inertia. Eliminate mechanical causes to prevent motor stall or replace the motor with one matched to the current mechanical system (inertia and power rating matched).”

Model
Inovance ISMH/ISMV series
Display shows
Inertia identification failure fault (Er.600)
Type
Fault code
Source
Manual p. 185

What Er.600 means

Inertia identification failure fault p. 190

Common causes

  • Inertia identification operation timed out p. 190

What to do

  1. Excessive load torque (e.g., motor stall) or excessive load inertia. Eliminate mechanical causes to prevent motor stall or replace the motor with one matched to the current mechanical system (inertia and power rating matched). p. 190

Before you service the product, read the safety instructions in the manual p. 186.

If Er.600 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.600; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.