This code indicates undervoltage, which can be caused by main circuit DC voltage undervoltage, DC bus voltage detected below 220V (380V) when using AC220V (AC380V) supply, or supply voltage being below the input voltage range. The manual's first action is: “Measure the supply voltage and adjust it to the normal range”
- Model
- Inovance ISMH/ISMV series
- Display shows
- Undervoltage (Er.410)
- Type
- Error code
- Source
- Manual p. 185
What Er.410 means
Undervoltage p. 190
Common causes
- Main circuit DC voltage undervoltage p. 190
- When using AC220V (AC380V) supply, DC bus voltage detected below 220V (380V); or supply voltage is below the input voltage range. p. 190
What to do
- Measure the supply voltage and adjust it to the normal range p. 190
Before you service the product, read the safety instructions in the manual p. 186.
If Er.410 is still not resolved
This page summarises what the manufacturer’s manual says about Er.410; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.