This code indicates motor encoder EEPROM data checksum error, which can be caused by abnormal parameters in motor encoder EEPROM, checksum error in serial encoder motor EEPROM, or serial motor not yet initialized with the H-type drive. The manual's first action is: “NO.1”
- Model
- Inovance ISMH/ISMV series
- Display shows
- Motor encoder EEPROM data checksum error (Er.136)
- Type
- Error code
- Source
- Manual p. 184
What Er.136 means
Motor encoder EEPROM data checksum error p. 184
Common causes
- Abnormal parameters in motor encoder EEPROM p. 184
- Checksum error in serial encoder motor EEPROM p. 184
- Serial motor not yet initialized with our H-type drive p. 184
- Motor memory failure p. 184
What to do
- NO.1 p. 184
- Reconnect the encoder wiring properly, or replace with the correct motor type p. 184
- Contact the manufacturer to rewrite motor parameters into the motor EEPROM p. 184
- Repair or replace the servo motor p. 184
Before you service the product, read the safety instructions in the manual p. 186.
If Er.136 is still not resolved
This page summarises what the manufacturer’s manual says about Er.136; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.