Motor overload means loaded operation exceeds the motor's inverse time curve overload time or mechanical factors prevent the motor from driving, causing excessive load during operation. The manual's first action is: “Confirm operating command and motor speed; improve mechanical factors”
- Model
- Inovance ISMH/ISMV series
- Display shows
- Motor overload (Er.620)
- Type
- Fault code
- Source
- Manual p. 185
What Er.620 means
Motor overload p. 190
Common causes
- Loaded operation exceeds the motor's inverse time curve overload time; UVW output may be missing a phase or have incorrect phase order. p. 190
- Mechanical factors prevent the motor from driving, causing excessive load during operation p. 190
- Servo drive fault p. 190
What to do
- Confirm operating command and motor speed; improve mechanical factors p. 190
- - It may be a servo drive fault; repair or replace the servo drive p. 190
Before you service the product, read the safety instructions in the manual p. 186.
If Er.620 is still not resolved
This page summarises what the manufacturer’s manual says about Er.620; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.